目的 探讨支气管套囊测压法及纤维支气管镜法判断左侧双腔支气管插管定位的准确性。方法 选择100例需左侧双腔支气管插管单肺通气行胸科手术的患者,随机分为两组,每组50例。双腔支气管插管后分别采用支气管套囊测压法及纤维支气管镜法判断双腔支气管的位置。结果 支气管套囊测压法、纤维支气管镜法定位准确率分别为88%、100%,纤维支气管镜法明显高于支气管套囊测压法(P<0.05)。两组插管后并发症差异无统计学意义(P>0.05)。结论 支气管套囊测压法简单实用,具较高的定位准确率和较低的并发症发生率。
Objective To compare the positioning accuracy of left double-lumen endobronchial tubes by bronchial cuff pressure method and fiberoptic bronchoscopy.Methods A total of 100 patients with single lung ventilation surgery were randomly divided into two groups, with 50 cases in each group.The position of double-lumen endobronchial tubes was assessed by bronchial cuff pressure method and fiberoptic bronchoscopy respectively after double-lumen bronchial intubation.Results The positioning accuracy rate of fiberoptic bronchoscopy (100%) was significantly higher than that of bronchial cuff pressure method (88%, P<0.05).There was no significant difference between the two groups in complications after intubation (P>0.05).Conclusion The bronchial cuff pressure method is simple and practical, with high positioning accuracy and low complications.
[1] 陈化雯,陈萍.双腔气管导管插管的可视化技术新进展[J].安徽医学, 2016,37(2):230-233.
[2] 刘志永,李荣江,丁翠青,等.不同定位方法在气胸患者双腔管定位中的效果比较[J].河北医科大学学报, 2016,37(4):459-461.
[3] Heir JS, Guo SL, Purugganan R, et al.A randomized controlled study of the use of video double-lumen endobronchial tubes versus double-lumen endobronchial tubes in thoracic surgery[J].J Cardiothorac Vasc Anesth, 2018,32(1):267-274.
[4] 李卉,张彬,包长顺.纤维支气管镜用于定位老年患者双腔支气管插管的研究[J].中国老年保健医学, 2017,15(1):28-29.
[5] Collins SR, Titus BJ, Campos JH, et al.Lung Isolation in the patient with a difficult airway[J].Anesth Analg, 2018,126(6):1968-1978.
[6] Clayton-Smith A, Bennett K, Alston RP, et al.A comparison of the efficacy and adverse effects of double-lumen endobronchial tubes and bronchial blockers in thoracic surgery: a systematic review and meta-analysis of randomized controlled trials[J].J Cardiothorac Vasc Anesth, 2015,29(4):955-966.
[7] Seo JH, Cho CW, Hong DM, et al.The effects of thermal softening of double-lumen endobronchial tubes on postoperative sore throat, hoarseness and vocal cord injuries: a prospective double-blind randomized trial[J].Br J Anaesth, 2016,116(2):282-288.
[8] 杨定东,王绍林,高俊,等.超声测量气管外径预测左侧双腔管型号的可行性[J].临床麻醉学杂志, 2015,31(4):405-407.
[9] 孙传玉,王月兰,李宗民.双腔支气管导管位置异常原因分析[J].临床麻醉学杂志, 2013,29(3):256-258.
[10] 韩亚升,张生茂,任志坚.体位改变对双腔支气管导管位置的影响作用[J].内蒙古医学杂志, 2013,45(6):721-722.
[11] Seo J H, Bae J Y, Kim H J, et al.Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques[J].BMC Anesthesiology, 2015,15(1):157.