目的 定量观测经皮弯角椎体成形术(percutaneous curved vertebroplasty, PCVP)后骨水泥分布特征。方法 测量并比较PCVP术后正位平片上骨水泥在椎体两侧的分布面积;建立术后椎体及骨水泥的三维模型,以椎体正中矢状面及轴面分割骨水泥模型,分别计算穿刺侧及对侧,上方及下方的骨水泥体积及占比,并进行统计学分析。结果 穿刺侧骨水泥面积2.19~6.08 cm2,平均(3.87±1.00) cm2;对侧骨水泥面积1.71~6.21cm2,平均(3.18±1.18) cm2,两侧差异有统计学意义(P<0.05)。穿刺侧骨水泥体积平均(4 821.7±1 151.8) mm3,占骨水泥总体积(62.2±10.4) %,占椎体体积(16.9±3.1) %;对侧骨水泥体积平均(2 982.5±1 207.9) mm3,占骨水泥总体积(37.8±10.4) %,占椎体体积(10.8±4.2) %,两侧相比均有统计学意义(P<0.05)。上方骨水泥体积平均 (4 242.9±1 165.8) mm3,占骨水泥总体积(55.2±15.1) %,占椎体体积(14.9±3.5) %;下方骨水泥体积平均(3 574.3±1 539.7) mm3,占骨水泥总体积(44.8±15.1) %,占椎体总体积(12.9±5.6) %,上下方相比,差异均无统计学意义(P>0.05)。结论 本研究定量观测并描述了PCVP术后骨水泥分布特征,并可为生物力学建模提供量化的临床数据。
Objective To quantitatively observe the bone cement distribution characteristics after percutaneous curved vertebroplasty (PCVP). Methods The distribution areas of cement in the ipsilateral and contralateral sides in anterior?posterior X-ray were calculated and compared. Three-dimensional models of vertebral body and bone cement were established. The bone cement was segmented into ipsilateral/contralateral part by sagittal plane, and upward/downward part by axial plane. Cement volume and volume ratio of each part were calculated, and statistical analysis was performed. Results The cement distribution areas in the ipsilateral side and the contralateral side were 2.19-6.08 cm2 [(3.87±1.00) cm2] and 1.71-6.21 cm2 [(3.18±1.18) cm2], with a statistical significant difference (P<0.05). In the ipsilateral part, the mean cement volume, volume ratio to the whole cement, and volume ratio to the whole vertebral body were (4 821.7±1 151.8) mm3, (62.2±10.4) %, and (16.9±3.1) %, respectively. Same parameters in the contralateral part were (2 982.5±1 207.9) mm3, (37.8±10.4) %, and (10.8±4.2) %, respectively; differences in the parameters between the two parts were statistically significant (P<0.05). These parameters in the upward part were (4 242.9±1 165.8) mm3, (55.2±15.1) %, and (14.9±3.5) %, respectively, compared to the downward part as (3 574.3±1 539.7) mm3, (44.8±15.1) %, and (12.9±5.6) %, respectively, with no statistical significance (P>0.05). Conclusion Through quantitatively observing and describing the characteristics of cement distribution after PCVP, the study provides quantitative data for biomechanical modeling.
[1] Clark W, Bird P, Gonski P, et al.Safety and efficacy of vertebroplasty for acute painful osteoporotic fractures (VAPOUR):a multicentre, randomised, double-blind, placebo-controlled trial[J].Lancet, 2016,388(10052):1408-1416.
[2] Sun H, Li C.Comparison of unilateral and bilateral percu-taneous vertebroplasty for osteoporotic vertebral compression fractures:a systematic review and meta-analysis[J].J Orthop Surg Res, 2016,11(1):156.
[3] Chen Q, Liu L, Liang G.Distribution characteristics of bone cement used for unilateral puncture percutaneous vertebroplasty in multiple planes[J].Orthopade, 2018,47(7):585-589.
[4] 贺宝荣, 许正伟, 郝定均,等.骨水泥在骨质疏松性骨折椎体内分布状态与生物力学性能的关系.中华骨科杂志[J],2012,32(8):768-773.
[5] 林玉江,林茜,杨利民,等.弯角椎体成形术治疗胸腰椎骨质疏松性椎体压缩骨折的疗效分析[J].中国脊柱脊髓杂志,2017,27(5):423-428.
[6] Liebschner M A, Rosenberg W S, Keaveny T M.Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty[J].Spine (Phila Pa 1976), 2001,26(14):1547-1554.
[7] Liang D, Ye L Q, Jiang X B, et al.Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis[J].J Surg Res, 2015,195(1):246-256.
[8] 杨惠林,刘强,唐海.经皮椎体后凸成形术的规范化操作及相关问题的专家共识[J].中华医学杂志,2018,98(11):808-812.
[9] 李玉伟,崔红领,王海蛟.应用可弯曲骨水泥注入器单侧穿刺行经皮椎体成形术的可行性及疗效[J].中华放射学杂志,2017,51(4):293-298.
[10] 印平. 骨质疏松性椎体压缩性骨折的治疗指南[J].中国骨质疏松杂志,2015,21(6):643-648.
[11] 常磊,谭祖明,唐肇毅.椎体后凸成形术治疗老年骨质疏松脊柱压缩骨折临床研究[J].外科研究与新技术,2017,6(1):30-32.
[12] Wang B, Zhao C P, Song L X, et al.Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral compression fracture: a meta-analysis and systematic review[J].J Orthop Surg Res, 2018,13(1):264.
[13] 杜心如,燕太强.经皮椎体成形术的解剖与临床[J].解剖与临床,2013,18(6):521-523.
[14] 周权发,刘宏建,寇红伟,等.弯角椎体成形装置的早期疗效评估及对骨水泥分布的影响[J].中国矫形外科杂志,2017,25(10):892-897.