Analysis of fault maintenance of oxygen concentration monitoring module for Drager Savina 300 ventilator

  • CAI Meihua
Expand
  • Medical Equipment Division, Shanghai First Maternity and Infant Hospital, Obstetrics and Gynecology Hospital, Tongji University, Shanghai 201204, China

Received date: 2025-07-15

Abstract

Objective To analyze the common fault causes and maintenance methods of the oxygen concentration monitoring module of Drager Savina 300 ventilator by studying typical cases to ensure the stable operation of medical equipment. Methods The process of case sharing involved ameticulous examination of each of the three cases, starting from the identification of fault phenomenon, followed by a systemic analysis of underlying fault causes, culminating in a step-by-step resolution according to established fault handling procedures. During maintenance, the maintenance mode detection was used to quickly locate problems; the step-by-step elimination method was adopted to narrow fault range; when deemed necessary, parts were replaced to ensure the restoration of equipment functionality. Results Oxygen concentration module faults were mostly related to air circuit tightness, oxygen valve components, and sensors. Checking and eliminating them one by one according to the air circuit diagram successfully solved different fault problems. All three cases were effectively repaired by this method, restoring the normal oxygen concentration monitoring function of the ventilator. Conclusion Ventilator maintenance requires accumulation and sharing of practical experience. Maintenance personnel should master various skills related to circuits and air circuits, and be proficient and specialized to ensure the reliable operation of medical equipment and provide strong guarantee for patient safety.

Cite this article

CAI Meihua . Analysis of fault maintenance of oxygen concentration monitoring module for Drager Savina 300 ventilator[J]. Surgical Research and New Technique, 2025 , 14(4) : 386 -390 . DOI: 10.3969/j.issn.2095-378X.2025.04.018

References

[1] 李毓顶. 呼吸机结构原理与常见故障检修[J]. 医疗装备,2014,27(5):79-80.
[2] 刘凯,徐恒,王贤卿,等. 德尔格Savina呼吸机工作原理与日常维护[J]. 湖北科技学院学报,2020,40(1):123-126.
[3] 卢岩,陈学超,金国春. Savina呼吸机及其潮气量低故障维修探讨[J]. 医疗卫生装备,2009,,30(10):127.
[4] 刘欣. DraegerSavina呼吸机常见故障的检修[J]. 医疗卫生装备,2011,32(2):139-140.
[5] 张健. 德尔格Savina呼吸机疑难故障维修三例[J]. 医疗装备,2022,35(21):143-146.
[6] 周跃. 德尔格Savina呼吸机的常见故障与维护[J]. 中国医疗器械信息,2025,31(2):138-140.
[7] 徐振新,华煜兰,杨宇峰. Savina呼吸机的常见故障维修思路及维护措施[J]. 医疗装备,2024,37(24):96-99.
[8] 黄龙生. 德尔格Savina呼吸机故障维修分析[J]. 中国医疗器械信息,2024,30(14):158-161.
[9] 宗华,宇应涛,褚代芳,等. 呼吸机故障智能诊断系统研究与开发[J]. 中国数字医学,2025,20(5):66-70.
[10] 傅守勇,张红梅. 德尔歌Savina重症监护呼吸机电源原理及检修分析[J]. 中国医学装备,2012,9(11):92-93.
[11] 张文亮,庞君晖,冯美燕,等. 有创呼吸机维修案例及维修模式探索[J]. 医疗装备,2024,37(3):101-103.
[12] 赵洪凤. 泰科PB840型医用呼吸机故障维修六例[J]. 医疗装备,2025,38(6):114-115.
[13] 刘涛. 迈瑞SV70S无创呼吸机故障维修二例[J]. 医疗装备,2025,38(3):100-101.
[14] 施志毅. SERVO-S呼吸机自检故障原因分析及故障维修简易操作流程[J]. 医疗装备,2021,34(11):130-131.
[15] 南智懿. Drager呼吸机常见故障2例[J]. 中国医疗器械信息,2019,25(17):181-182.
[16] 刘庆涛,张慧勇. 呼吸机空气氧气混合及气路控制工作原理及常见故障分析[J]. 中国医学装备,2025,22(1):158-161.
[17] 金铭. 德尔格Evita V300呼吸机的气路故障维修思路与维护保养[J]. 医疗装备,2025,38(7):109-111.
[18] 秘甲文. 有创呼吸机故障排除与维修技术研究[J]. 中国医疗器械信息,2025,31(2):145-148.
[19] 刘涛. 迈瑞SV70S无创呼吸机故障维修二例[J]. 医疗装备,2025,38(3):100-101.
[20] 张园. 迈瑞SV300呼吸机气路故障维修实例[J]. 医疗装备,2024,37(2):122-124.
[21] 黎容容. 迈瑞SV300呼吸机的故障分析与维护质控[J]. 医疗装备,2024,37(1):112-114.
Outlines

/