Objective To reduce the incidence of complications caused by excessive tourniquet pressure by modifying the setting of pneumatic tourniquet pressure in lower limb surgery.Methods Seventy patients whose expected operation time was less than 90 min under general anesthesia were randomly divided into two groups.In the control group, the pressure of pneumatic tourniquet was set at twice the systolic blood pressure measured with a non-invasive cuff on the upper arm of the patient and locked.In the improved group, the pressure of pneumatic tourniquet was set at 130% of the systolic blood pressure measured with a non-invasive cuff on the lower limb of the healthy side and with a tourniquet applied to a specific location on the limb of the affected side and locked.The blood pressure measurements of right upper limb and unaffected lower limb were observed and recorded after anesthesia.Comparisons were made on indicators such as intraoperative hemorrhage, tourniquet shock, skin conditions where tourniquet was applied at the end of the operation, pains where tourniquet was applied on the first day after the operation, and paresthesia of the affected limb.Results There was no significant difference between the two groups in the proportion of patients requiring pressure release (P=0.051) and intraoperative hemorrhage (P>0.05).The skin conditions of the improved group was better than that of the control group (P<0.05).The postoperative pain degree of the improved group was lower than that of the control group (P<0.001).There were no complications such as tourniquet shock and associated paresthesia in both groups.Conclusion Setting pneumatic tourniquet pressure according to the systolic blood pressure of the unaffected lower limb could achieve a good hemostasis during a fast lower limb surgery.
YAO Ying
,
SUN Xiaomin
. Clinical observation on modified setting of pneumatic tourniquet pressure in lower limb surgery[J]. Surgical Research and New Technique, 2019
, 8(3)
: 211
-215
.
DOI: 10.3969/j.issn.2095-378X.2019.03.018
[1] 石永萍,马莉,王子莲.电动气压止血带在骨科手术中的应用[J].实用医技杂志. 2015,22(12):1356-1357.
[2] 王娟,刘敏.气压止血带在四肢手术中的应用及研究进展[J].中国实用护理杂志, 2006,22(5):72-74.
[3] 张国英.电动气压止血带的安全使用[J]. 临床医药文献电子杂志, 2017,4(22):4199.
[4] 王晓宁,施莺莺,严彬,等.下肢手术中设定空气止血带个体化充气压力的探讨[J].护理研究, 2012,26(16):1453-1455.
[5] 邓广肖.气压止血带在四肢手术中的应用研究[J].护理研究, 2017,31(6):650-652.
[6] 焦明海.气压止血带对下肢静脉血栓形成的影响[J].中国实用乡村医师杂志, 2013,18(1):25-26.
[7] 张宏杰.上肢气囊止血带最佳充气压力的探究[J].齐齐哈尔医学院学报, 2008,29(12):1532-1532.
[8] 崔振吉,王奎书,郑素婷.气囊止血带在骨科手术应用中不良反应的研究[J].护理研究, 2006,20(9):2266-2267.
[9] 马琼.预防性护理对减少气压止血带所致皮肤损伤的作用[J].现代临床护理, 2011,10(2):40-41.
[10] 杨建平,蒋涛,吕正祥.止血带优化对全膝关节置换术快速康复的影响[J].中国矫形外科杂志, 2018,26(1):33-37.
[11] 王桂珍,崔瑞芳.使用气压止血带的不良反应分析与对策[J].全科护理, 2011,9(2):150-150.