《中国期刊全文数据库》收录期刊
《中国核心期刊(遴选)数据库》收录期刊
《中文科技期刊数据库》收录期刊
Original article

Clinical analysis on minimally invasive stabilization system in the treatment of complicated fracture of distal femur

  • FENG Jishun ,
  • CHEN Kefeng ,
  • HONG Xinggao ,
  • LIU Ming ,
  • HUANG Shijian ,
  • LIANG Wangban
Expand
  • Department of Orthopedics, Guangdong Yangjiang People’s Hospital, Yangjiang 529500, China

Received date: 2017-12-22

  Online published: 2019-12-12

Abstract

Objective To assess the clinical value of minimally invasive stabilization system in the treatment of complicated fracture of distal femur.Methods Sixty-two patients with complicated fracture of distal femur treated from February 2015 to February 2017 were selected in the study. The subjects were randomly divided into a test group and a control group according to random number table, with 31 cases in each group. The test group adopted an approach using minimally invasive stabilization system; while the control group used internal fixation with anatomic plate. Operation time, intraoperative bleeding volume, and bone healing conditions were compared between the two groups.Results The test group showed less operation time, intraoperative bleeding volume,and bone healing time than the control group (P<0.05). The excellent and good rate of knee joint function recovery of the test group (90.32%) was significantly higher than that of the control group (67.74%) (P<0.05).Conclusion The minimally invasive stabilization system has an obvious effect on complicated fracture of distal femur, showing shortened operation time and less body injury, which is worthy of clinical application.

Cite this article

FENG Jishun , CHEN Kefeng , HONG Xinggao , LIU Ming , HUANG Shijian , LIANG Wangban . Clinical analysis on minimally invasive stabilization system in the treatment of complicated fracture of distal femur[J]. Surgical Research and New Technique, 2018 , 7(1) : 35 -37 . DOI: 10.3969/j.issn.2095-378X.2018.01.010

References

[1] Weight M, Collinge C.Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2,A3,C2,and C3)[J].J Orthop Trauma,2004,18(8):503-508.
[2] 王立江,李兰涛,樊巍,等.微创稳定系统(LISS)治疗股骨远端复杂骨折的临床观察[J].中国美容医学杂志,2012,21(10):165-166.
[3] Kolb W, Guhlmann H, Windisch C, et al.Fixation of distal femoral fractures with the less invasive stabilization system:a minimally invasive treatment with locked fixed-angle screws[J].J Trauma,2008,65(6):1425-1434.
[4] 吾布力.微创稳定系统和解剖钢板治疗股骨远端复杂骨折的临床疗效[J].按摩与康复医学,2012,3(30):212-213.
[5] Kayali C, Agus H, Turgut A.Successful results of minimally invasive surgery for comminuted supracondylar femoral fractures with LISS: comparative study of multiply injured and isolated femoral fractures[J].J Orthop Sci,2007,12(5):458-465.
[6] 曹宇星.微创稳定系统治疗胫骨近端复杂骨折28例观察[J].大家健康(下旬版),2017,11(1):132-133.
[7] Phisitkul P, Mckinley TO, Nepola JV, et al.Complications of locking plate fixation in complex proximal tibia injuries[J].J Orthop Trauma,2007,21(2):83-91.
[8] 肖海军,薛锋,何志敏,等.微创固定治疗不稳定骨盆骨折42例临床分析[J].中国骨与关节损伤杂志,2011,26(10):902-903.
Outlines

/