Objective To investigate the effects of different early fluid management approaches on the death risk of patients with septic shock.Methods Basic information, SOFA score, and daily intake and output volume of 119 patients with septic shock were collected. Correlation between liquid volume and outcome of patients with septic shock was analysed based on the liquid intake and output volume.Results The daily fluid balance in the first two days of the dead group was significantly higher than that of the survival group (P=0.031). The survival rate was significantly lower in the patients in the third quartile of 2-day cumulative fluid balance versus those in the first quartile (P=0.037). After 2 days of shock, the death risk in the high SOFA score group (>5 points) was higher than that in the low SOFA score group (<5 points) (P<0.001). The death risk was increased to 2.957 times in the patients in the third quartile of 2-day cumulative fluid balance (P=0.012).Conclusion The septic shock patients’ prognosis is related to the volume of early fluid input. The patients with a large volume of fluid intake showed poor prognosis. The SOFA score can reflect the severity of septic shock patients.
ZHOU Juan
,
WU Gang
,
ZHANG Lei
. Effect of early fluid management on survival of patients with septic shock[J]. Surgical Research and New Technique, 2018
, 7(1)
: 54
-57
.
DOI: 10.3969/j.issn.2095-378X.2018.01.015
[1] Guillamet MC,Rhee C,Patterson AJ.Cardiovascular management of septic shock in 2012[J].Curr Infect Dis Rep,2012,14(5):493-502.
[2] Levy MM, Fink MP, Marshall JC, et al.2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference[J].Crit Care Med,2003,31(4):1250-1256.
[3] Sirvent JM, Ferri C, Baro A, et al.Fluid balance in sepsis and septic shock as a determining factor of mortality[J].Am J Emerg Med,2015,33(2):186-189.
[4] Rivers E, Nguyen B, Havstad S, et al.Early goal-directed therapy in the treatment of severe sepsis and septic shock[J].N Engl J Med,2001,345(19):1368-1377.
[5] Mouncey PR, Osborn TM, Power GS, et al.Trial of early, goal-directed resuscitation for septic shock[J].N Engl J Med,2015,372(14):1301-1311.
[6] Investigators A,Group ACT,Peake SL,et al.Goal-directed resuscitation for patients with early septic shock[J].N Engl J Med,2014,371(16):1496-1506.
[7] Pro CI, Yealy DM, Kellum JA, et al. A randomized trial of protocol-based care for early septic shock[J].N Engl J Med,2014,370(18):1683-1693.
[8] Azevedo LC, Park M, Salluh JI, et al. Clinical outcomes of patients requiring ventilatory support in Brazilian intensive care units: a multicenter,prospective,cohort study[J].Crit Care,2013,17(2):R63.
[9] Liu V,Morehouse JW,Soule J,et al.Fluid volume,lactate values,and mortality in sepsis patients with intermediate lactate values[J].Ann Am Thorac Soc,2013,10(5):466-473.
[10] Rosenberg AL, Dechert RE, Park PK, et al. Review of a large clinical series: association of cumulative fluid balance on outcome in acute lung injury: a retrospective review of the ARDS net tidal volume study cohort[J].J Intensive Care Med,2009,24(1):35-46.
[11] National Heart,Blood Institute Acute Respiratory Distress Syndrome Clinical Trials, Wiedemann HP, et al. Comparison of two fluid-management strategies in acute lung injury[J].N Engl J Med,2006,354(24):2564-2575.
[12] Murphy CV, Schramm GE, Doherty JA, et al. The importance of fluid management in acute lung injury secondary to septic shock[J].Chest,2009,136(1):102-109.
[13] Boyd JH, Forbes J, Nakada TA, et al.Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality[J].Crit Care Med,2011,39(2):259-265.
[14] Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares[J].Chest,2008,134(1):172-178.
[15] Marik PE, Cavallazzi R.Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense[J].Crit Care Med,2013,41(7):1774-1781.
[16] Cecconi M, De Backer D, Antonelli M, et al. Consensus on circulatory shock and hemodynamic monitoring.Task force of the European Society of Intensive Care Medicine[J].Intensive Care Med,2014,40(12):1795-1815.
[17] Freitas FG, Bafi AT, Nascente AP, et al. Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies[J].Br J Anaesth,2013,110(3):402-408.
[18] Hong DM, Lee JM, Seo JH, et al. Pulse pressure variation to predict fluid responsiveness in spontaneously breathing patients: tidal vs.forced inspiratory breathing[J].Anaesthesia,2014,69(7):717-722.
[19] Benomar B, Ouattara A, Estagnasie P, et al. Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test[J].Intensive Care Med,2010,36(11):1875-1881.
[20] Lanspa MJ, Grissom CK, Hirshberg EL, et al. Applying dynamic parameters to predict hemodynamic response to volume expansion in spontaneously breathing patients with septic shock: reply[J].Shock,2013,39(5):462.
[21] Kent A,Bahner DP,Boulger CT,et al.Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility index[J].J Surg Res,2013,184(1):561-566.